Avery-dennison Platinum 6039 JavaScript Manual do Utilizador Página 16

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 94
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 15
2-4 Programmer’s Manual
2. Configure the control scanning attributes and the attributes for each
bar code. For example,
<SCRIPT src="./jsUltra.js"></SCRIPT>
<SCRIPT type="text/javascript">
UPCEAN.EnableUPCA = true
UPCEAN.EnableUPCE = false
</SCRIPT>
<BODY>
<OBJECT id=”UPCEAN” style="LEFT: 0px; WIDTH: 0px; TOP: 0px;
HEIGHT: 0px"
classid=clsid:67A4B8A3-A9E5-4757-97EC-2D052AEDE521>
</OBJECT> //Instantiate Class
</BODY>
3. Call the CommitConfigChanges function to save the new settings.
For example,
<SCRIPT src="./jsUltra.js"></SCRIPT>
<SCRIPT type="text/javascript">
SCANNER.CommitConfigChanges()
</SCRIPT>
<BODY>
<OBJECT id=”SCANNER” style ="LEFT: 0px; WIDTH: 0px; TOP: 0px;
HEIGHT: 0px"
classid=clsid: AD3C761C-4BCC-403D-A68D-128ED702A417>
</OBJECT> //Instantiate Class
</BODY>
Vista de página 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 93 94

Comentários a estes Manuais

Sem comentários